TPO POC tie-breaking sensitivity

Apply a maximum-count, midpoint-distance, lower-row tie hierarchy.

0%

What you will learn

Prerequisites: TPO maxima, profile midpoint and deterministic tie rules.

Mechanism and decision rules

A TPO profile can have several rows with equal maximum counts. A deterministic implementation must select one or report a tie. One documented convention chooses the tied row closest to the midpoint of the profile’s price range, then the lower row if distance also ties. This lesson uses that hierarchy explicitly; other conventions should be labeled rather than assumed wrong.

Tie-breaking is a display or analytical convention, not additional evidence that the selected row contains more participation. A small extension at an extreme can move the range midpoint and change the selected POC even if all tied row counts stay unchanged. Report the tied region and neighboring counts when the exact chosen price is sensitive to this rule.

Worked example · synthetic data

Synthetic rows 100,102 and 104 each have five TPOs, and the profile range is 100–104. Midpoint is 102, so the hierarchy selects 102. Now one new TPO appears at 110. The three maximum rows still tie at five, but the range midpoint becomes 105. Distances are 5,3 and 1, so the selected POC becomes 104.

No extra TPO was added to 104. The selected level changed because a low-count extreme changed the midpoint used to resolve the tie. Treating that shift as a strong migration signal would overstate what happened.

Failure modes and limits

Profile midpoint can mean different things in different software; verify whether it uses price-range midpoint or another definition. Row labels and tick rounding matter. A tie-sensitive POC should not be presented as a uniquely dominant auction price. Later corrections can alter both extremes and counts.

Practice case

Rows 200 and 204 tie at the maximum and the full range is 200–204. Under midpoint proximity then lower-row preference, which POC is selected? What if a new one-count row appears at 208 without changing the tie counts?

Reveal the worked answer

Initially midpoint 202 leaves both maxima two units away, so 200 is selected by the lower-row rule. With the range extended to 208, midpoint 204 selects 204 directly. The leading counts did not change; the tie-break reference did.

Check your understanding

Does the selected POC necessarily have more TPOs than every other row?


Explanation

A tie-breaking convention can choose among equal maxima.

Why can one low-count extreme change a tied POC?


Explanation

The secondary criterion depends on range geometry.

What is the honest interpretation of a tie-sensitive selection?


Explanation

The display choice adds no new trading activity.